Toshiba Magnia 3310 User Manual
Page 100
Hardware Diagnostics
Items of Hardware Diagnostics
96
At the start of the test, the message to change the Hardware
Diagnostics test diskette with the test diskette appears. Change
disks at this point.
[01. Sequential address read]
This subtest reads data from all tracks continuously on a
diskette.
[02. Random address data W/R/C]
This subtest writes random data to random addresses on all
tracks on the diskette. The data is then read and compared to
the original data.
NOTE: This test requires that the test diskette be formatted
and write-enabled.
Make sure that there is no important data on the test diskette,
as the contents may be modified during the test.
FLOPPY DISK TEST (FDD) Error log
*Address during the test (ADDRESS: 0tthss)
0 tt h ss
tt
: Track address
h
: Head address
ss
: Sector address
Status
Error name
Meaning
01
BAD COMMAND ERROR
Bad command error has occurred
02
ADDRESS MARK NOT FOUND
The address mark has not been found
03
WRITE PROTECED
Floppy disk is write-protected
04
RECORD NOT FOUND
The record has not been found
06
MEDIA CHANGE LINE ERROR
The media change line is bad
08
DMA OVERRUN ERROR
DMA OVERRUN occurred
09
DMA BOUNDARY ERROR
DMA BOUDARY occurred
10
CRC ERROR
CRC check error
20
FDC ERROR
FDC error
40
SEEK ERROR
Floppy disk seek error