Page 3

background image

—3—

RECOMMENDED TUBE DIAMETERS

* For tube sets between 50 and 175 ft, consult Residential Split System Long-Line Application Guideline.

CHECK-FLO-RATER® PISTON

* Piston listed is for any approved non-capillary tube coil combination. Piston is

shipped with outdoor unit and must be installed in an approved indoor coil.

UNIT

SIZE

LIQUID TUBE DIAMETER (IN.)

VAPOR TUBE DIAMETER (IN.)

0 to 50 Ft

Tube Length

Long-Line Applications*

0 to 50 Ft

Tube Length

Long-Line Applications*

(Maximum Diameter)

018, 024

3/8

3/8

5/8

3/4

030, 036

3/4

7/8

042, 048

7/8

1-1/8

060

1-1/8

1-1/8

UNIT SIZE—SERIES

PISTON*

IDENTIFICATION NO.

018-C, D

55

024-C, D

57

030-C, D

67

036-C, D

73

042-C, D

78

048-C

82

060-C

96

CERTIFICATION APPLIES ONLY

WHEN THE COMPLETE SYSTEM

IS LISTED WITH ARI.