DETAILED COOLING CAPACITIES* Continued

NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.

* Detailed cooling capacities are based on indoor and outdoor unit at same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor

unit is located above outdoor unit, a slight variation in capacity may occur.

† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F entering air at the indoor coil. For sensible capacities at other than 80°F, deduct 835 Btuh per 1000 CFM of

indoor coil air for each degree below 80°F, or add 835 Btuh per 1000 CFM of indoor coil air per degree above 80°F. When the required data falls between
the published data, interpolation may be performed.

** Unit kW is total of indoor and outdoor unit kilowatts.

EVAPORATOR

AIR

CONDENSER ENTERING AIR TEMPERATURES °F

85

95

105

115

125

CFM

EWB

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

593C060-C Outdoor Section With CC5A/CD5AW060 Indoor Section

1750

72

66.9

33.0

5.85

63.9

31.9

6.39

60.7

30.7

6.97

57.3

29.5

7.61

53.8

28.2

8.29

67

61.1

41.8

5.70

58.3

40.6

6.23

55.4

39.4

6.80

52.3

38.1

7.43

48.9

36.8

8.09

62

55.7

50.3

5.56

53.1

49.0

6.08

50.4

47.6

6.65

47.5

46.0

7.25

44.0

43.8

7.86

57

53.2

53.2

5.50

51.3

51.3

6.03

49.1

49.1

6.61

46.7

46.7

7.22

43.8

43.8

7.86

2000

72

68.1

34.5

5.98

64.9

33.3

6.52

61.6

32.1

7.11

58.1

30.9

7.74

54.4

29.6

8.43

67

62.3

44.2

5.82

59.3

43.0

6.35

56.2

41.8

6.93

53.0

40.5

7.56

49.5

39.2

8.22

62

56.8

53.4

5.69

54.1

52.0

6.21

51.3

50.4

6.78

48.5

48.4

7.39

45.5

45.5

8.04

57

55.2

55.2

5.65

53.1

53.1

6.18

50.8

50.8

6.76

48.4

48.4

7.39

45.4

45.4

8.04

2250

72

69.0

35.8

6.10

65.7

34.7

6.64

62.3

33.4

7.23

58.7

32.2

7.87

55.0

30.9

8.55

67

63.1

46.6

5.95

60.1

45.4

6.48

56.9

44.1

7.05

53.6

42.8

7.68

50.0

41.5

8.35

62

57.7

56.2

5.81

55.0

54.5

6.33

52.3

52.3

6.90

49.7

49.7

7.54

46.8

46.8

8.21

57

56.9

56.9

5.79

54.7

54.7

6.32

52.3

52.3

6.91

49.7

49.7

7.54

46.8

46.8

8.21

Multipliers for Determining the Performance With Other Indoor Sections

Indoor

Section

Unit
Size

Cooling

Indoor

Section

Unit
Size

Cooling

Capacity

Power

Capacity

Power

CC5A/CD5AA

060

0.96

0.98

CK5A/CK5BT

060

0.97

0.95

CC5A/CD5AW

060

1.00

1.00

CK5A/CK5BX

060

0.98

0.93

CE3AA

060

1.01

1.00

COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE

CK3BA

060

0.96

0.98

CC5A/CD5AA

060

0.96

0.95

CK5A/CK5BA

060

0.96

0.98

CC5A/CD5AW

060

0.97

0.94

CK5A/CK5BN

060

0.96

0.99

CE3AA

060

0.98

0.95

CK5A/CK5BX

060

1.00

1.00

CK3BA

060

0.97

0.95

F(A,B)4(A,B)N(F,B)

060

1.01

1.04

CK5A/CK5BA

060

0.97

0.95

FB4(A,B)NB

070

1.03

1.02

CK5A/CK5BT

060

0.97

0.95

FC4(B,C)N(F,B)

060

1.01

1.04

CK5A/CK5BX

060

0.98

0.93

FC4(B,C)NB

070

1.03

1.02

COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE

FG3AAA

060

0.99

0.99

CC5A/CD5AA

060

0.96

0.94

FK4(C,D)NB

006

1.02

0.98

CC5A/CD5AW

060

0.97

0.94

COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE

CE3AA

060

0.98

0.94

CC5A/CD5AA

060

0.96

0.95

CK3BA

060

0.97

0.95

CE3AA

060

0.98

0.94

CK5A/CK5BA

060

0.97

0.95

CK3BA

060

0.97

0.95

CK5A/CK5BT

060

0.97

0.95

CK5A/CK5BA

060

0.97

0.95

CK5A/CK5BX

060

0.98

0.93