DETAILED COOLING CAPACITIES*
See notes on page 24.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
85
95
105
115
125
CFM
EWB
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
593C018-C, D Outdoor Section With CC5A/CD5AA018 Indoor Section
525
72
19.7
9.50
1.69
18.6
9.09
1.80
17.5
8.66
1.91
16.3
8.23
2.01
15.2
7.80
2.12
67
17.9
11.8
1.65
16.8
11.4
1.75
15.8
10.9
1.85
14.7
10.5
1.94
13.6
10.0
2.04
62
16.1
14.0
1.60
15.1
13.6
1.70
14.1
13.0
1.79
13.1
12.5
1.88
12.1
12.0
1.96
57
15.0
15.0
1.58
14.3
14.3
1.68
13.5
13.5
1.77
12.8
12.8
1.86
12.0
12.0
1.95
600
72
20.1
9.89
1.73
19.0
9.47
1.84
17.8
9.03
1.95
16.6
8.60
2.06
15.4
8.17
2.16
67
18.3
12.5
1.68
17.2
12.0
1.79
16.1
11.6
1.89
15.0
11.1
1.99
13.8
10.6
2.08
62
16.5
14.9
1.64
15.5
14.4
1.74
14.4
13.8
1.83
13.4
13.2
1.92
12.4
12.4
2.01
57
15.7
15.7
1.62
14.9
14.9
1.72
14.1
14.1
1.82
13.3
13.3
1.91
12.5
12.5
2.01
675
72
20.5
10.3
1.76
19.3
9.83
1.88
18.1
9.39
1.99
16.9
8.95
2.09
15.6
8.51
2.20
67
18.6
13.1
1.72
17.5
12.6
1.83
16.3
12.2
1.93
15.2
11.7
2.03
14.0
11.2
2.13
62
16.8
15.8
1.68
15.8
15.2
1.78
14.7
14.5
1.87
13.7
13.7
1.97
12.7
12.7
2.06
57
16.2
16.2
1.67
15.4
15.4
1.77
14.6
14.6
1.87
13.7
13.7
1.97
12.9
12.9
2.06
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Unit
Size
Cooling
Indoor
Section
Unit
Size
Cooling
Capacity
Power
Capacity
Power
CC5A/CD5AA
018
1.00
1.00
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
024
1.03
1.01
CC5A/CD5AA
018
1.00
0.91
CC5A/CD5AA
024
1.03
1.01
024
1.02
0.91
CE3AA
024
1.05
1.01
CC5A/CD5AW
024
1.02
0.91
CF5AA
024
1.05
1.01
CE3AA
024
1.02
0.91
CK3BA
024
1.03
1.01
CK3BA
024
1.02
0.89
CK5A/CK5BA
018
1.00
1.01
CK5A/CK5BA
018
1.00
0.89
024
1.03
1.01
024
1.02
0.89
CK5A/CK5BW
024
1.03
1.01
CK5A/CK5BW
024
1.02
0.89
F(A,B)4(A,B)NF
018
0.99
1.00
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
024
1.05
1.02
CC5A/CD5AA
018
1.02
0.93
FC4(B,C)NF
024
1.05
1.02
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
FF1DNA
018
0.99
1.00
CC5A/CD5AA
018
1.02
0.93
024
1.05
1.02
CK5A/CK5BW
024
1.02
0.94
FG3AA
024
1.02
1.01
CK3BA
024
1.02
0.94
FK4(C,D)NF
001
1.05
0.94
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
002
1.05
0.94
CC5A/CD5AA
018
1.02
0.93
—
—
—
CK3BA
024
1.02
0.94
—
—
—
CK5A/CK5BW
024
1.02
0.94