beautypg.com

3 status notification setting, Status notification setting -88, Status notification setting – Konica Minolta bizhub C353 User Manual

Page 101

background image

C353/C253/C203

1-88

Setup items by operation

1

1.31.3

Status Notification Setting

In Administrator mode of PageScope Web Connection, select the Maintenance tab - "Status Notification
Setting" - "E-mail Address" - [Edit].

Specify the following settings.

Max Mail Size

Select whether to limit the size of sent messages.

Server Capacity

To limit the maximum mail size, specify the max. allowance
of the mail size including the attached file.
Mails exceeding the maximum allowance are removed.
If a mail is separated, this setting is disabled.

Receiving limit of the
server

Admin. E-mail Address

Displays the administrator address.
If the administrator address is not specified, specify it at
"Machine Setting".

Address for the adminis-
trator

Binary Division

To divide an E-Mail, select the "Binary Division" check box.
If the mail software used for receiving mails does not have
the mail restore function, the mails may not be read.

Restore function of the
mail soft

Divided Mail Size

To divide the mail, specify a divided mail size.

Receiving limit of the
server

Item

Definition

Prior confirmation

Item

Definition

Prior confirmation

Notification Address

Specify the notification address.

Notification address

Replenish Paper Tray

Provides notification when a paper-out condition occurs.

JAM

Provides notification when a paper misfeed occurs.

PM Call

Provides notification when a periodic inspection is required.

Replace Staples

Provides notification when a staple-out condition occurs.

Replenish Toner

Provides notification when a toner-out condition occurs.

Finisher Tray Full

Provides notification when the finisher tray becomes full.

Service Call

Provides notification when a service call occurs.

Job Finished

Provides notification when the job is completed.

This manual is related to the following products: