Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice

8

61182301E1-5A

OPERATION

The NTU-8F provides a platform to exchange data between four G.703 interfaces and an
optical fiber interface. The customer data connection is via the RJ-45 connector on the unit.
An optical fiber interface is provided for communication with the loop. The NTU-8F operates
with an LTU-8 at the other end of the fiber optic cable.

FRONT PANEL PUSHBUTTON

Pushbuttons on the front panel (

Table 5

) provide the following functionality (when the option

is enabled on the LTU-8).

Table 5. Front panel Pushbuttons

Pushbutton

Function

Port Select

Press the

PORT SELECT

button to select the active port. Selection

choices cycle through the provisioned G.703 E1 ports in following

order:
No Port, Port 1, Port 2, Port 3, and Port 4.

Local Loop/ERR INJ

With a port selected, and a Bit Error Rate Test (BERT) is not in

progress, press the

LOCAL LOOP/ERR INJ

button to either initiate or

terminate a local loop on the selected port.
If a BERT is in progress, press the button to inject a single bit error.

Remote Loop

With a port selected, press the

REMOTE LOOP

button to place or

remove a remote loop on the selected port's single data service. This
action sends respective inband loop-up or loop-down patterns to
the far end (in the associated data service timeslots).

BERT

With a port selected, and no local loops, press the

BERT

button to

start or stop a BERT on the selected port.