Replacing the projection lamp – Kodak DP2000 User Manual
Page 44

User’s Guide KODAK DP2000 Digital Projector
38
Replacing the Projection Lamp
&DXWLRQ 7R DYRLG EXUQV DOORZ WKH SURMHFWRU WR FRRO IRU DW OHDVW
PLQXWHV EHIRUH \RX RSHQ WKH ODPS PRGXOH GRRU 1HYHU
H[WUDFW WKH ODPS PRGXOH ZKLOH WKH ODPS LV RSHUDWLQJ
The lamp hour counter in the Status menu counts the number of hours
the lamp has been in use. Replace the lamp when the brightness is no
longer acceptable. You can order new lamp modules from your dealer
of KODAK products.
Follow these steps to replace the projection lamp:
1. Turn off the projector by unplugging the power cord.
2. Wait 30 minutes to allow the lamp to cool thoroughly.
3. Invert the projector on a flat surface, then insert a small
screwdriver or other flat object into the tab on the lamp module
door.
4. Pull the lamp door up and remove it.
&DXWLRQ 1HYHU RSHUDWH WKH SURMHFWRU ZLWK WKH ODPS GRRU RSHQ RU
UHPRYHG 7KLV GLVUXSWV WKH DLU IORZ DQG FDXVHV WKH
SURMHFWRU WR RYHUKHDW