beautypg.com

Cd a, Junior – Vollrath JUNIOR Out-of-Chamber Vacuum Pack Machine User Manual

Page 20

background image

20

VACUUM PACKING MACHINE

CONDITIONNEUSE SOUS VIDE

MAQUINA DE VACÍO

Operating and service manual / Mode d’emploi et d’entretien

Manual de uso y mantenimiento / Ed. 01 - 2011

REV. 00 - Cod.: 1500387

EN

JUNIOR

Fig. 1

3.3

VACUUM CREATION INSIDE OF CONTAINERS

• Connect the appliance to a power socket.
• Switch the machine on by pressing the button (1) ON/OFF” until all the lights on the buttons come on briefly.
• Lift the machine lid (A).
• Place the special suction tube equipped with vacuum fitting on the nozzle (B) located inside the gasket.
• Undo the ring nut (C) of the valve located on the cover of the container to be used so that the inside gasket can move.
• Place the cover on the container (jar, pot, bowl, etc.) inside of which the vacuum is to be created.
• Fix the evacuation fitting (D) on the cover valve.
• Press the button “PUMP” and press down hard on the cover at first (Fig. 1) to create a minimum vacuum inside the container; the machine will then

create the complete vacuum and, once reached, the machine will automatically turn off and be ready for a new cycle.

• Screw down the valve ring nut to prevent the return of the air.

B

C

D

A

3.4

STOPPING OF PACKAGING CYCLE

If the packaging cycle has to be stopped for any reason, (suction of liquids, bag not correctly positioned, etc.) carry out the following:

• Press the button (1) ON/OFF” to stop the appliance.

• Press the button (1) ON/OFF” again to release the movable lid (A - Fig. 2).

Fig. 2

A

VACUUM CREATION

Container and related components not