Page B-2
History Group
The History group records periodic statistical samples from the 
collision domain and stores them in an SNMP table for later 
retrieval. 
The History group allows the manager to set a timer to record 
samples of Ethernet statistics. It allows baselining of network 
activity over time.
Once samples are taken, the sample data is stored in an entry in 
a media-specific table. Each such entry defines one sample and 
is associated with the historyControl entry that caused the 
sample to be taken. The only media-specific table defined is the 
etherHistoryTable for Ethernet networks. 
Alarm Group
The Alarm group periodically takes statistical samples from 
variables and compares them to previously configured 
thresholds. The alarm table stores configuration entries, each of 
which defines a polling period and various threshold values.
If a monitored variable exceeds a threshold value, the switch 
generates an event. No more events are generated for that 
threshold until the opposite threshold is exceeded. 
You can limit the generation of events via the MIB. When 
sampling a delta value, you can increase the precision of the 
sample by taking the sample twice per period and comparing 
the sum of the latest two samples to the threshold. This allows 
the switch to detect threshold crossings that span the sampling 
boundary. This does not require any special configuration of 
the threshold value.
This group requires the implementation of the Event Group.