Status Monitoring and Statistics
Page 6-8
Counter
Description
RXAlignErrors
For the 10Mbps ports, the counter
records alignment errors.
For the 100Mbps ports, the counter
records the sum of alignment errors and 
code errors (frames received with 
rxerror signal).
RXOversize
The total number of packets received
that were longer than 1518 octets in 
length (excluding framing bits, but 
including FCS octes) and were otherwise 
normal.
RXJabbers
The total number of packets received that 
were longer than 1518 octets (excluding 
framing bits, but including FCS octets), 
and had either an FCS error or an 
alignment error.
RXUndersize
The total number of packets received
with less than 64 octets (excluding 
framing bits, but including FCS octets) 
and were otherwise normal.
RXFragments
The total number of packets received
that were not an integral number of 
octets in length or that had a bad FCS, 
and were less than 64 octets in length 
(excluding framing bits but including 
FCS octets).
Pkt64
The total number of packets (including
error packets) received with 64 octets 
(excluding framing bits, but including 
FCS octets).
Pkt65-127
The total number of packets (including
error packets) received that were 
between 65 and 127 octets in length 
(excluding framing bits, but including 
FCS octets).