beautypg.com

Table 9. channel fractional volume settings, 13 channel mute (address 13h), 1 independent channel mute (chxx_mute) – Cirrus Logic CS44800 User Manual

Page 60: 14 channel invert (address 14h), 1 invert signal polarity (chxx_inv)

background image

60

DS632F1

CS44800

7.13

Channel Mute (address 13h)

7.13.1

Independent Channel Mute (CHXX_MUTE)

Default = 0
0 - Disabled
1 - Enabled
Function:

The PWM outputs of the CS44800 will mute when enabled. The muting function is affected, similar to at-
tenuation changes, by the Soft and Zero Cross bits (SZC[1:0]).

7.14

Channel Invert (address 14h)

7.14.1

Invert Signal Polarity (CHXX_INV)

Default = 0
0 - Disabled
1 - Enabled
Function:

When enabled, these bits will invert the signal polarity of their respective channels.

CHXX_IVOL[7:0]

CHXX_FVOL(1:0)

Volume Setting

0001 1000

00

+24.00 dB

0001 0111

10

+23.50 dB

0000 0001

11

+1.75 dB

0000 0001

00

+1.00 dB

0000 0000

01

+0.25 dB

0000 0000

00

0 dB

1111 1111

10

-0.50 dB

1111 1111

00

-1.00 dB

1111 1110

11

-1.25 dB

1111 1101

10

-2.50 dB

1000 0010

00

-126.00 dB

1000 0001

11

-126.25 dB

1000 0001

00

-127.00 dB

Table 9. Channel Fractional Volume Settings

7

6

5

4

3

2

1

0

CHB4_MUTE

CHA4_MUTE

CHB3_MUTE

CHA3_MUTE

CHB2_MUTE

CHA2_MUTE

CHB1_MUTE

CHA1_MUTE

7

6

5

4

3

2

1

0

CHB4_INV

CHA4_INV

CHB3_INV

CHA3_INV

CHB2_INV

CHA2_INV

CHB1_INV

CHA1_INV