beautypg.com

Figure 3. i2c control port timing, Cs4391a, Switching characteristics - i – Cirrus Logic CS4391A User Manual

Page 11: C control port

background image

CS4391A

DS600PP3

11

SWITCHING CHARACTERISTICS - I

2

C CONTROL PORT

(Inputs: logic 0 = AGND,

logic 1 = VL)

Notes: 7. Data must be held for sufficient time to bridge the 300 ns transition time of SCL.

Parameter

Symbol

Min

Max

Unit

I

2

C

®

Mode

SCL Clock Frequency

f

scl

-

100

KHz

RST Rising Edge to Start

t

irs

500

-

ns

Bus Free Time Between Transmissions

t

buf

4.7

-

µs

Start Condition Hold Time (prior to first clock pulse)

t

hdst

4.0

-

µs

Clock Low time

t

low

4.7

-

µs

Clock High Time

t

high

4.0

-

µs

Setup Time for Repeated Start Condition

t

sust

4.7

-

µs

SDA Hold Time from SCL Falling

(Note 7)

t

hdd

0

-

µs

SDA Setup time to SCL Rising

t

sud

250

-

ns

Rise Time of Both SDA and SCL Lines

t

r

-

1

µs

Fall Time of Both SDA and SCL Lines

t

f

-

300

ns

Setup Time for Stop Condition

t

susp

4.7

-

µs

t

buf

t

hdst

t

hdst

t

lo w

t r

t f

t

hdd

t high

t sud

t sust

t susp

Stop

S tart

S ta rt

Stop

R e p e a te d

S D A

S C L

t

irs

R S T

Figure 3. I

2

C Control Port Timing