Characteristics and specifications, Recommended operating conditions, Absolute maximum ratings – Cirrus Logic CS4354 User Manual
Page 5
DS895F2
5
CS4354
2. CHARACTERISTICS AND SPECIFICATIONS
RECOMMENDED OPERATING CONDITIONS
GND = 0 V; all voltages with respect to ground.
Notes: 1.
Device functional operation is guaranteed within these limits. Functionality is not guaranteed or implied
outside of these limits. Operation outside of these limits may adversely affect device reliability.
ABSOLUTE MAXIMUM RATINGS
GND = 0 V; all voltages with respect to ground.
WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation
is not guaranteed at these extremes.
Notes: 2.
The maximum over/under voltage is limited by the input current except on the power supply pin.
Parameters
Symbol Min Typ
Max
Units
DC power supply
Analog power
Interface power
VA
VL
4.75
1.4
5.0
1.8, 3.3, 5.0
5.25
5.25
V
V
Ambient operating temperature (power applied)
-CSZ
T
A
-40
-
+85
°C
Parameters
Symbol
Min
Max
Units
DC power supply
Low voltage analog power
Interface power
VA
VL
-0.3
-0.3
6.0
6.0
V
V
Input current, any pin except supplies
I
in
-
±10
mA
Digital input voltage
Digital interface
V
IN-L
-0.3
VL+ 0.4
V
Ambient operating temperature (power applied)
T
A
-55
+125
°C
Storage temperature
T
stg
-65
+150
°C