Digital interface characteristics, Internal power-on reset threshold voltages, Figure 4. power-on reset threshold sequence – Cirrus Logic CS4354 User Manual
Page 10: Table 1. power-on reset threshold voltages, Cs4354 digital interface characteristics

10
DS895F2
CS4354
DIGITAL INTERFACE CHARACTERISTICS
Test conditions (unless otherwise specified): GND = 0 V; all voltages with respect to ground.
INTERNAL POWER-ON RESET THRESHOLD VOLTAGES
Test conditions (unless otherwise specified): GND = 0 V; all voltages with respect to ground.
Table 1. Power-On Reset Threshold Voltages
Figure 4. Power-On Reset Threshold Sequence
Parameters
Symbol Min Typ
Max
Units
High-level input voltage
1.8 V
VL 5.0 V
V
IH
0.7xVL
-
-
V
Low-level input voltage
1.8 V
VL 5.0 V
V
IL
-
-
0.3xVL
V
Input leakage current
I
in
-
-
±10
A
Input capacitance
-
8
-
pF
Parameters
Symbol
Min
Typ
Max
Units
Internal reset asserted at power-on
V
on1
-
0.2
-
V
Internal reset released at power-on
V
on2
-
3.6
-
V
Internal reset asserted at power-off
V
off
-
3.1
-
V
VA
V
on2
V
on1
V
off
GND
HI
LO
No Power
reset
undefined
reset
active
DAC
Ready
reset
active
reset