5 predefined sample scripts, Cdb4244 – Cirrus Logic CDB4244 User Manual
Page 12

12
DS900DB2
CDB4244
2.5
Predefined Sample Scripts
The CDB4244 FlexGUI software comes furnished with four scripts that can quickly configure the board for
use with an external S/PDIF transmitter and receiver. These scripts configure the CS4244, CS8416, and
CS8406 to operate using the 24-bit Left-Justified serial interface format, with a master clock rate of 256
times the sample rate. The sample rate is set within the external S/PDIF source. System timing is mastered
by the CS8416 at multiples of the sample rate set by the S/PDIF source.
The system master clock recovered by the CS8416 is passed through the CS2000 before being presented
to the CS4244 and the CS8406. Serial audio data from the incoming S/PDIF stream is routed from the
CS8416 to the SDIN1 and SDIN2 pins of the CS4244, while data on the SDOUT1 pin of the CS4244 is rout-
ed to the CS8406 to be sent along the outgoing S/PDIF stream. The CS4244 is configured to operate in
single-speed mode; see the CS4244 data sheet for the range of allowable incoming sample rates. The four
scripts are defined as follows:
See
regarding VA supply selection.
QuickSetup_Coax_VA_3R3V_AIN12:
Configures the CDB4244 as described above when an exter-
nal S/PDIF transmitter is connected to the “S/PDIF IN” input of
the board using a coaxial cable, and a 3.3-V supply is used to
power VA.
QuickSetup_Coax_VA_5V_AIN12:
Configures the CDB4244 as described above when an exter-
nal S/PDIF transmitter is connected to the “S/PDIF IN” input of
the board using a coaxial cable, and a 5-V supply is used to
power VA.
QuickSetup_Optical_VA_3R3V_AIN12: Configures the CDB4244 as described above when an exter-
nal S/PDIF transmitter is connected to the “S/PDIF IN” input of
the board using an optical cable, and a 3.3-V supply is used to
power VA.
QuickSetup_Optical_VA_5V_AIN12:
Configures the CDB4244 as described above when an exter-
nal S/PDIF transmitter is connected to the “S/PDIF IN” input of
the board using an optical cable, and a 5-V supply is used to
power VA.