WIKA DI35 User Manual
Page 46

6 Commissoning, operation
46
WIKA operating instructions digital indicator DI35-M
PN
Function
Range of values
De-
fault
User-
level
7 = switch-on locking by both
Linearization
100
Number of additional
setpoints
0…30
0
2
101
…
130
Setpoints 1…30
-9999…99999
2
180
Totalizer function
0 = off
1 = Totalizer without
permanent saving (Reset
by boot-up)
2 = Totalizer with permant
saving
0
3
181
Time base of display value
for totalizator function
0 = second
1 = minute
2 = hour
0
3
182
Factor for totalizer value
(in powers of 10)
0 = 1…6 = 1.000.000
0
3
183
Decimal point for totalizer
value
00000…0,0000
0
3
184
Counter value in digit (for
Reset through 0, too), inital
value aswell
0…99999
0
3
185
Activator for counter reset
on 0
(multi-function key or digital
input: push for at least
50 ms)
0 = no reset source
1 = by multi-function key
2 = by external input
3 = by multi-function key and
digital input
4 = UP and DOWN while
showing totalisator value
0
3
186
Change display on
totalizator value
0 = no change
1 = by multi-function key
2 = by digital input
0
3
Information
200
Serial number
0…99999
0
8