WIKA DI35 User Manual
Page 10
3 Specifications
10
WIKA operating instructions digital indicator DI35-M
{Switching outputs}
number and type
2 or 4 change-over contacts (relays), fully
programmable
Load
AC 230 V, 5 A (ohmic load) or
DC 30 V, 2 A (ohmic load)
Switching cycles
0.5 * 10
5
at max contact rating
5 * 10
6
mechanically
Separation as per DIN EN 50178
Characteristic data as per DIN EN 60255
{Serial Interface}
RS 232, selectable with or without galvanic
isolation or
RS 485 (only for point-to-point connection),
selectable with or without galvanic isolation
Protocol
manufacturer-specific ASCII
communication
9600 Baud, no parity, 8 data bits, 1 stop bit
Lead length
RS 232: max. 3 m
RS 485: max. 1000 m
Case
Material
PC polycarbonate, ABS Blend, UL 94V-0,
black
Ingress protection
Front: IP 54, {IP 65};
Back: IP 00 (per IEC 60529 / EN 60529)
Weight
Approx. 450 g
Dimensions
96 x 48 x 148 mm (w x h x d) including plug-in
terminals
Mounting
snap-in screw element for wall thickness up to
50 mm
Permissible ambient conditions
Operating temperature
0…60 °C
Storage temperature
-20…80 °C
Humidity
0…75 % relative humidity, non-condensing
CE conformity
EMC directive
2004/108/EC, EN 61326 emission (group 1,
class B) and interference immunity (industrial
application)
Low voltage directive
2006/95/EG, EN 61010-1
{ } Items in curved brackets are optional extras for additional price.