CPT6200 Pressure Transmitter specific details:

Pressure connection

G½ B; {flush diaphragm (G1 for 0.1 up to 1.6 bar) or various connection
adapters on request}

Material wetted parts

Wetted parts stainless steel, case stainless steel;
flush diaphragm version: stainless steel {Hastelloy C4};
O-Ring

2)

: NBR {FKM/FPM or EPDM}

Internal transmission fluid

Synthetic oil, (only for pressure ranges up to 16 bar or flush
diaphragm), {Halocarbon oil for oxygen applications}

3)

;

{Listed by FDA for food industry}

One year stability

0.2 % of span at reference conditions

Permissible
- medium temperature

3)

-25 ... +100 °C

- ambient temperature

0 ... 50 °C

- storage temperature

-40 ... +80 °C

Compensated range

0 ... 70 °C

Temperature coefficients
- mean TC of zero signal

0.2 %/10 K

- mean TC of span

0.2 %/10 K

Connection to CPH6200

via 1 m cable (plug and play); on request: up to 5 m

Weight

approx. 220 g

2) O-ring made of Viton or EPDM for flush diaphragm with integrated cooling element.
3) The oxygen version must not be used with medium temperatures higher than 60 °C.

Cannot be manufactured for absolute pressure ranges < 1 bar abs.