21

WIKA operating instructions level switch model LSD-30

GB

Display mode

▲ ▼

Long pressing of the "MENU" key

Programming mode

Factory setting:

▲ ▼

SP1 / FH1

Value

Min: MBA + 0.5 %, Max: MBE

MBE

▲ ▼

RP1 / FL1

Value

Min: MBA, Max: SP1 -0.5 %

MBE -10 %

▲ ▼

SP2 / FH2

Value

Min: MBA + 0.5 %, Max: MBE

MBE

▲ ▼

RP2 / FL2

Value

Min: MBA, Max: SP2 -0.5 %

MBE -10%

▲ ▼

EF

RES

Yes / No

Reset to factory setting

▲ ▼

DS1

Value

0 ... 50 s

0 s

▲ ▼

DR1

Value

0 ... 50 s

0 s

▲ ▼

DS2

Value

0 ... 50 s

0 s

▲ ▼

DR2

Value

0 ... 50 s

0 s

▲ ▼

OU1

PARA

HNO, HNC, FNO, FNC

HNO

▲ ▼

OU2

PARA

HNO, HNC, FNO, FNC

HNO

▲ ▼

UNIT

Unit

mm, cm, inch, %

order-related

▲ ▼

SETR

4 mA / 0 V

Value

MBA + max. 25 % of span

MBA

▲ ▼

20 mA / 10 V

Value

MBE - max. 25 % of span

MBE

OFS

Yes / No

Offset adjustment 1,500 mm maximum

0 mm

▲ ▼

ACT, HIGH, LOW, OFF, SP1/FH1, RP1/FL1,

SP2/FH2, RP2/FL2

ACT

DISM

PARA

▲ ▼

DISR

Yes / No

Rotate display by 180°

▲ ▼

RHL

Yes / No

Reset HIGH, LOW

▲ ▼

PAS

Value

Password

without

▲ ▼

TAG

Value

Measuring point number

without

▲ ▼

Legend:

MBA = Start of measuring range

MBE = End of measuring range

END

END

▼ ▼

▼ ▼

Display mode

11613033.01 01/2012 GB/D/F/E

6. Commissioning, operation

Menu (programming and factory setting)