3. Specifications

3. Specifications

Specifications

DELTA-trans model DPGT40

Mechanical data

Nominal size

Differential pressure indication: Ø 100 mm

Working pressure indication: Ø 22 mm

Accuracy class

Differential pressure indication: ≤ 2.5 % of span (option

≤ 1.6 %)

Working pressure indication: 4

Scale ranges (EN 837)

Differential pressure: 0 ... 0.25 to 0 ... 10 bar

Working pressure: 0 ... 25 bar

Max. working pressure (stat.)

25 bar

Overpressure safety

Either side max. 25 bar

Permissible temperatures

Ambient: -10 ... +70 °C, medium: -10 ... +90 °C

Storage: -40 ... +70 °C

Ingress protection

IP 54 per EN 60529 / IEC 60529

Media chamber (wetted)

Aluminium, EN AC–Al Si9Cu3(Fe), black lacquered

Process connections (wetted)

2 x G 1/4 female, lower mount (LM), in-line, centre

distance 26 mm

Pressure elements (wetted)

Differential pressure: Compression springs from stain-

less steel 1.4310 and separating diaphragm from FPM/

FKM (option: NBR)

Working pressure: Bourdon tube from Cu-alloy

Transmission parts (wetted)

Stainless steel 1.4301, 1.4305, 1.4310, FPM/FKM (op-

tion: NBR)

Sealings (wetted)

FPM/FKM (option: NBR)

Movement

Copper alloy, wear parts argentan

Dial

Differential and working pressure indication: White dial,

black lettering

Pointer

Differential and working pressure indication: Blue pointer

Zero adjustment for differential

pressure indication

Via screw in the dial

Case

Aluminium, EN AC–Al Si9Cu3(Fe), black lacquered

Window

Plastic

Weight

approx. 1.3 kg