beautypg.com

3 cabling for the sv-306 and sv-307, 9 grounding the wall plate, Cabling for the sv-306 and sv-307 – Kramer Electronics SV-552ALC User Manual

Page 34: Grounding the wall plate, On 8.3

background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Grounding the Wall Plate

30

• Each wire protrudes 9mm in length from the plastic insulation so that it

can be easily connected. To prevent the wires crossing, be sure that each
wire is completely inserted

• With STP cable, the GND pin is used for shielding. Shielding is not

needed, but if desired, connect to the GND pin of the PC

8.3 Cabling for the SV-306 and SV-307

Kramer engineers have developed special twisted pair cables to best match
our digital twisted pair products; the Kramer BCP-DGKat524 (CAT 5 24
AWG), and the Kramer BCP-DGKat623 (CAT 6 23 AWG cable). These
specially built cables significantly outperform regular CAT 5/CAT 6 cables.

A system range of up to 90m (295ft) at 1080i/SXGA, or up to 30m (98ft) at
1080p/UXGA on shielded BCP-DGKat524 cable; 90m (295ft) at 1080i, or
up to 70m (230ft) at 1080p/UXGA on shielded BCP-DGKat623 cable.

Note that the STP cable Ground shield must be connected/soldered to the
connector shield.

9 Grounding the Wall Plate

The grounding screw is used to earth the chassis of the unit to the ground of
the building, thus preventing static electricity from interfering with the
product’s performance.

Table 15

defines the grounding screw components.

Table 16: Grounding Screw, Lock Washers and Ring Tongue Terminal

#

Item

1

M3X6 screw

2

1/8" Toothed Lock Washer

3

M3 Ring Tongue Terminal

To ground a wall plate:

1. Connect the Ring Tongue terminal to the building grounding point wire

(it is recommended to use a green-yellow AWG#18 wire, crimped with a
proper hand-tool).

2. Insert the M3x6 screw through the toothed lock washers and the tongue

terminal in the order shown above.

3. Insert the M3x6 screw (with the two toothed lock washers and ring

tongue terminal) into the grounding screw hole and tighten the screw.
Wiring the K-Net™ Connector:

This manual is related to the following products: