9 default communication parameters, Default communication parameters, Section – Kramer Electronics VS-88DTP User Manual
Page 38: 9default communication parameters

34
VS-88DTP - Default Communication Parameters
9
Default Communication Parameters
EDID
EDID data is passed between Output 1 and Input 1
RS-232
Protocol 2000
Protocol 3000 (Default)
Baud Rate:
9600
Baud Rate:
115,200
Data Bits:
8
Data Bits:
8
Stop Bits:
1
Stop Bits:
1
Parity:
None
Parity:
None
Command Format:
HEX
Command Format:
ASCII
Example (Output 1 to
Input 1):
0x01, 0x81, 0x81,
0x81
Example (Output 1 to
Input 1):
#AV 1>1
Switching Protocol
P2000 -> P3000
P3000 -> P2000
Command:
0x38, 0x80, 0x83,
0x81
Command:
#P2000
Ethernet
Default Settings
Reset Settings
IP Address: 192.168.1.39
Power cycle the unit while holding in the
Factory Reset button, located on the rear
panel of the unit.
TCP Port #: 5000
UDP Port #: 50000
The Windows®-based Kramer control software (available for
download the latest software from our Web site at
http://www.kramerelectronics.com)
operates with protocol 2000.
If the
VS-88DTP is set to protocol 3000, it is automatically switched
to protocol 2000