VS-88DTP - Connecting the VS-88DTP
5.2
Connecting a PC or Controller to the RS-485 Port
You can operate the
VS-88DTP via the RS-485 port from a distance of up to
1200m (3900ft) using any device equipped with an RS-485 port (for example, a
PC). For successful communication, you must set the RS-485 machine number
and bus termination.
To connect a device with a RS-485 port to the VS-88DTP:
•
Connect the A (+) pin on the RS-485 port of the PC to the A (+) pin on the
RS-485 port on the rear panel of the
VS-88DTP
•
Connect the B (–) pin on the RS-485 port of the PC to the B (–) pin on the
RS-485 port on the rear panel of the
VS-88DTP
•
Connect the G pin on the RS-485 port of the PC to the G pin on the RS-485
port on the rear panel of the
VS-88DTP
5.2.1
Setting the RS-485 Machine Number
When several
VS-88DTP units are connected, the machine number determines
the unique identity of the
VS-88DTP on the bus (see
Note:
•
When using a stand-alone
VS-88DTP unit, set the machine number to 1
(factory default)
•
When connecting more than one
VS-88DTP, set the first machine
(connected via RS-232) to be machine number 1. The other
VS-88DTP units must each be set to a unique machine number between 2
and 16
The machine number on the
VS-88DTP is set using the DIP-switches on the rear
panel.
To set the RS-485 machine number using the DIP-switches:
illustrates the factory default MACH # DIP-switch settings.