Connecting Your VS-44HDxl 3G HD/SD-SDI 4x4 Matrix Switcher

13

6.3 Dipswitch Setting

By default, all the dipswitches are set to OFF. Figure 4 illustrates the

VS-44HDxl

dipswitches:

ON

1 2 3 4

SETUP

Figure 4: VS-44HDxl SETUP Dipswitches

6.3.1

Setting the Machine # Dipswitches

The Machine # determines the position of a

VS-44HDxl unit, specifying which

VS-44HDxl unit is being controlled when several VS-44HDxl units connect to a

PC or serial controller. Set the Machine # on a

VS-44HDxl unit via SETUP DIPS

1, 2, 3 and 4, according to Table 3.
When using a standalone

VS-44HDxl unit, set the Machine # to 1. When

connecting more than one

VS-44HDxl unit, set the first machine (the Master) that

is closest to the PC, as Machine # 1 (dipswitches are set to OFF).

Table 3: Machine # Dipswitch Settings

Mach. #

DIP 1

DIP 2

DIP 3

DIP 4

1 (default) OFF

OFF

OFF

OFF

2

OFF

OFF

OFF

ON

3

OFF

OFF

ON

OFF

4

OFF

OFF

ON

ON

5

OFF

ON

OFF

OFF

6

OFF

ON

OFF

ON

7

OFF

ON

ON

OFF

8

OFF

ON

ON

ON