beautypg.com

Kramer Electronics VP-300T User Manual

Page 8

background image

Overview

5

For a CAT 5 cable exceeding a distance of 50m, separate power supplies

should be connected to the transmitter and to the receiver simultaneously.

3.2 Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP)

We recommend that you use shielded twisted pair (STP) cable. There are

different levels of STP cable available, and we advise you to use the best

quality STP cable that you can afford. Our STP skew-free cable, Kramer

BC-SXTP, is intended for transmitting VGA signals. Our non-skew-free

cable, Kramer

BC-STP, is intended for digital signals.

The compliance to electromagnetic interference was tested using STP

cables, therefore we recommend using those cables.
Although unshielded twisted pair (UTP) cable might be preferred for long

range applications, the UTP cable should be installed far away from electric

cables, motors and so on, which are prone to create electrical interference.

However, since the use of UTP cable may not conform to electromagnetic

standards, Kramer does not commit to meeting the standard with UTP cable.

3.3 Recommendations for Achieving the Best Performance

To achieve the best performance:

Connect only good quality connection cables, thus avoiding

interference, deterioration in signal quality due to poor matching,

and elevated noise- levels (often associated with low quality

cables)

Avoid interference from neighboring electrical appliances and

position your Kramer machines away from moisture, excessive

sunlight and dust

Caution

– No operator-serviceable parts inside unit.

Warning

– Use only the Kramer Electronics input power

wall adapter that is provided with this unit

1

.

Warning

– Disconnect power and unplug unit from wall

before installing or removing device or servicing unit.

1 For example, part number 2535-000251

This manual is related to the following products: