Using the EDID Button
Initially, the VM-28H/VM-216H operates with the factory default EDID.
You can acquire the EDID from:
One output (the selected output LED illuminates)
The default EDID (all the output LEDs flash)
Several connected outputs, the Auto-mix Mode (the output LEDs flash in
sequence)
The EDID acquired is a weighted average of all the connected outputs. For example, if
several displays with different resolutions are connected to the outputs, the acquired
EDID supports all the resolutions, as well as other parameters included in the EDID
To cycle between the different modes (One Output, Default and Auto-mix), press
the input button (IN 1 or IN 2) to which you want to read the EDID, as defined in
the following table. Note, that the EDID feature has a 10 second timeout.
Current
EDID Mode
Appearance
To cycle to the
Default EDID
To cycle to the
Auto-mix EDID
To cycle to the
One output EDID
One output
The selected
output LED
illuminates
Press the IN button
once again after
selecting output 8
(for VM-28H) or
output 16 (for
VM-216H). The
output LEDS flash
Default
The output LEDs
flash
Press the IN button
once
Auto-mix
The output LEDs
flash in
sequence
Press the IN button
to select the
required output.
The selected
output flashes
To acquire or change the EDID of a new output display from:
One output, see
Section
The default EDID, see
Section
Several connected outputs, see
Section