beautypg.com

Button operation scaling instructions, System id / pad location change – Mittler Bros Machine & Tool 50220-OLD User Manual

Page 2

background image

Please read all instructions prior to operating scales.

1

. Set all scale pads out individually (at least 12" apart).

2.

Turn on the scale pads by switching the power switch on each

scale pad to "ON" and press the reset button on the front of the

black box.(Green light will start blinking indicating power is on.)

3.

Pivot the hand held antenna until the antenna is perpindicular to the floor

(this is essential for communication between the pads and hand held) and turn

the hand held on by pushing the "ON/OFF" button.

4.

When the menu appears, select "Weigh Vehicle" by pressing the "OK" but-

ton. Give the hand held a few seconds to start communication with the scale

pads. When the red lights on ALL scale pads are blinking and numbers appear

on the scaling screen the scales are ready to use. If you find that one scale does

not blink red after 1 minute, simply turn that scale off and back on and press

the reset button.

5.

Zero the system (if necessary) by pushing the "MENU" button and selecting

zero all pads. This will then display zero's in the locations selected. (this may

take a few seconds)

6.

Put your racecar on the scales and the weights will register, the %'s and

totals will show on the display.

7.

Turn the hand held off by pushing the "ON/OFF" button for 2 seconds.

8.

Turn the scale pads off to conserve battery life.

9.

The hand held unit contains rechargeable batterys, simply re-

charge by plugging the power adapter into the unit. For best performance,

charge battery for 12 hours. Each scale pad contains (4) AA batteries.

Button Operation

Scaling Instructions

TURNS UNIT ON OR OFF

SELECTS DESIRED FUNCTION

System ID / Pad Location Change

If you wish to change a pad location (ex. change the RF to the LR etc.) or change

the system ID, this can be done by following these steps.

1.

Set all scale pads out individually (at least 12" apart).

2.

Turn on the scale pads by switching the power switch on each scale pad to

"ON" and press the reset button on the front of the black box.(Green light will

start blinking indicating power is on.)

3.

Pivot the hand held antenna until the antenna is perpindicular to the floor (this

is essential for communication between the pads and hand held) and turn the hand

held on by pushing the "ON/OFF" button.

4.

When the menu is displayed on the hand held, select "SYSTEM ID". Scroll

the arrow down to the word ID and press the right arrow over to where the name

is. When a character is underlined, you can change it to whatever you wish using

the up and down arrows, this will make your system unique so no one else with

a wireless scale system can pick up on your "channel" and see your information.

Once you are finished scroll back completely to the left and back up until the ar-

row is pointiong to "Save and Exit" then press "OK".

5.

Plug the communications cable into the hand held and into one scale pad.

6. Press "MENU" and scroll down past "UNITS" & "PAD SETUP"

will appear. This will allow you to change pad location and/or download a new

system ID. Scroll the arrow down until it is pointed at the pad you are plugged

into (RF,LF,RR or LR) and press "OK". You will see a message scroll across the

bottom of the screen and the message "Pad set OK" will flash. Plug the cable into

every scale pad to complete this step, each time selecting the pad you are plugged

into. Once you have completed all 4 scale pads, you must turn the pads off by flip-

ping the switch to "OFF"and turn the hand held off by pressing the "ON/OFF"

button for 2 seconds.

7.

Complete steps 1-5 of the scaling instructions and your scales are now ready to

be used.

8.

Turn the scale pads and hand held off to conserve battery life.

DISPLAYS THE MENU

TURNS BACKLIGHT ON

SCROLLING ARROWS

Thank you for your business.

CAUTION: Changes or modifications not expressly approved by the party

responsible for compliance could void the user's authority to operate the

equipment.