beautypg.com

Goulds Pumps VIC - IOM User Manual

Page 8

background image

Safety regulations for Ex-approved products in potentially explosive
atmospheres

Description of ATEX

The ATEX directives are a specification enforced in Europe for electrical and non-electrical equipment.
ATEX deals with the control of potentially explosive atmospheres and the standards of equipment and
protective systems used within these atmospheres. The relevance of the ATEX requirements is not limited
to Europe. You can apply these guidelines to equipment installed in any potentially explosive atmosphere.

General guidelines

WARNING:
Installation, Operation, and Maintenance manuals clearly identify accepted methods for disassembling
units. These methods must be adhered to. Trapped liquid can rapidly expand and result in a violent
explosion and injury. Never apply heat to impellers, propellers, or their retaining devices to aid in their
removal.

If there are any questions regarding these requirements, the intended use, or if the equipment requires
modification, contact an ITT representative before you proceed.

Personnel requirements

ITT disclaims all responsibility for work done by untrained and unauthorized personnel.
These are the personnel requirements for Ex-approved products in potentially explosive atmospheres:

• All work on the product must be carried out by certified electricians and ITT-authorized mechanics.

Special rules apply to installations in explosive atmospheres.

• All users must know about the risks of electric current and the chemical and physical characteristics of

the gas and/or vapor present in hazardous areas.

• The maintenance operation for Ex-approved products must be made in conformity to the

international or national standards (IEC/EN 60079-17).

Product and product handling requirements

These are the product and product handling requirements for Ex-approved products in potentially
explosive atmospheres:

• Only use the product in accordance with the approved motor data stated on the nameplates.
• The Ex-approved product must never run dry during normal operation. Dry running during service

and inspection is only permitted outside the classified area.

• Never start a pump with a closed suction valve or blocked suction line.
• Before you start working with the product, make sure that the product and the control panel are

isolated from the power supply and the control circuit, so they cannot be energized.

• Do not open the product while it is energized or in an explosive gas atmosphere.
• Make sure that thermal contacts are connected to a protection circuit according to the approval

classification of the product.

• Intrinsically safe circuits are normally required for the automatic level-control system by the level

regulator if mounted in zone 0.

• The yield stress of fasteners must be in accordance with the approval drawing and the product

specification.

• Make sure that the equipment is properly maintained:

• Monitor the pump components and the end temperature of the liquid.
• Maintain proper bearing lubrication.

• Do not modify the equipment without approval from an authorized ITT representative.
• Only use parts that have been provided by an authorized ITT representative.

Introduction and Safety (Continued)

6

Model VIC Installation, Operation, and Maintenance