Troubleshooting

Operation troubleshooting

Symptom

Cause

Remedy

Pump does not start.

The electrical circuit is open or not

complete.

Check the circuit and make any necessary

corrections.

The impellers are binding against the bowls. Reset the impeller adjustment. See Installation

for details.

The electric driver is not receiving enough

voltage.

Make sure that the driver is wired correctly and

receiving full voltage.

The motor is defective.

Consult an ITT representative.

The pump is not delivering liquid.

The bowl assembly is not submerged

enough.

Adjust the liquid level in the sump as

necessary.

The suction strainer is clogged.

Remove the obstructions.

There is an obstruction in the liquid

passage.

Pull the pump and inspect the impeller and

bowl.

The discharge head is not properly vented. Open the vent.

The pump is not delivering enough

liquid.

The suction or discharge valves are closed. Open the valves. For more information, see

Commissioning, Operation, Startup, and

Shutdown.

The pump is not producing the

rated flow or head.

The impellers are not rotating fast enough. Make sure that the driver is wired correctly and

receiving full voltage.

The impellers are rotating the wrong

direction.

Make sure the impellers are spinning

counterclockwise when viewed from above.

Check the engagement of the motor coupling.

The total pump head is too high.

Check the pipe friction losses. Use larger

discharge piping.

The liquid passages are partially obstructed. Inspect the impellers and bowls and remove

any obstructions.

There is cavitation.

Insufficient NPSH is available.

The impellers are too high (semi-open

construction only).

Reset the impeller adjustment. See Installation

for details.

There is not enough pressure.

The impellers are not rotating fast enough. Make sure that the turbine is receiving full

steam pressure.

The liquid passage is obstructed.

Inspect the impellers and bowls and remove

any obstructions.

The impellers are rotating in the wrong

direction.

Make sure the impellers are spinning

counterclockwise when viewed from above.

Check the engagement of the motor coupling.

The impellers are too high (semi-open

construction only).

Reset the impeller adjustment. See Installation

for details.

Troubleshooting

58

Model VIC Installation, Operation, and Maintenance