beautypg.com

Goulds Pumps VIC - IOM User Manual

Page 30

background image

Runout of

driver shaft

Procedure

3. Slowly rotate the driver shaft 360°.
4. Check that the face of the seal housing is square with the shaft to within 0.002 in.

(0.05 mm) TIR.

Concentricity

of the seal

housing

This measurement requires that you remove the mechanical seal.
1. Install the dial indicator as shown.
2. Rotate the driver shaft by hand and run the indicator in the inside-machined

surface of the seal housing in order to determine the concentricity.

3. If the indicator reads higher than 0.004 in. (0.10 mm) TIR, loosen the four driver

hold-down bolts and relocate the driver on the motor base register.

Installation (Continued)

28

Model VIC Installation, Operation, and Maintenance