Vi. options & accessories – Myron L 729II User Manual
Page 64

60
VI. OPTIONS & ACCESSORIES
A. OPTIONS ORDERED WITH MONITOR/CONTROLLER
PART #
DESCRIPTION
-SC
Second Alarm/control Module (Monitor/controllers only)
-4A
4-20mA Self-Powered Isolated Output Module (digital models only)
-PA
70 db Piezo Electric Alarm (mounted on front panel) (digital Monitor/controller models only)
-PAT
Piezo Alarm and Timer Module (digital Monitor/controller models only)
-35BL
3 1/2 Digit Backlit Liquid Crystal Display (LCD)
-45BL
4 1/2 Digit Backlit Liquid Crystal Display (LCD)
-TP
Temperature Module 0-200°C, Requires -TP Sensor (digital Monitor/controllers only)
-TH
TP/TPO Alarm/control Harness (requires SC & TP above) (digital models only)
-PC
Power cord 115VAC (8 ft./2,44 meters with USA plug and strain relief)
SPECIAL ORDER OPTIONS
-24VA
24 VAC Isolated Power Supply
-24VD
24 VDC Isolated Power Supply
-PTS
Panel mounted full scale test switch
-SFP
Panel mounted set point adjustment (digital Monitor/controllers only)
-TPA
Temperature Module 0-200°C, above -TP with adjustable hysteresis, (digital models only)
-HT
High Temperature modification for -HT sensors, range limited (contact Myron L technical sales)
B. OPTIONS & ACCESSORIES ORDERED SEPARATELY
PART #
DESCRIPTION
ASI
AQUASWITCH I™, fully automatic RO/DI switching system (requires Monitor/controller)
SCO
Second Alarm/control Module only (Monitor/controllers only)
4AO
4-20mA Self-Powered Isolated Output Module (digital models only)
3SE
3 Sensor Input Module with Enclosure
3SO
3 Sensor Input Module with 1 meter/3 ft. Cable*
3RE
3 Range Switch with Enclosure (Add C=Cond or R=Res)
3RO
3 Range Switch with 1 meter/3 ft. cable (Add C=Cond or R=Res)*
3SRE
Above 3SO and 3RO combined with Enclosure (Add C=Cond or R=Res)
3SRO
Above 3SO and 3RO combined (Add C=Cond or R=Res)*
PAO
Piezo Electric Alarm only (digital Monitor/controllers only)
PATO
Piezo Alarm and Timer Module (digital Monitor/controllers only)
35BLO
3 1/2 Digit Backlit Liquid Crystal Display (LCD)
45BLO
4 1/2 Digit Backlit Liquid Crystal Display (LCD)
TPO
Temperature Module 0-200°C, Requires -TP Sensor (digital models only)
THO
TP/TPO Alarm/control Harness only (requires SCO and TPO above)
TPC
Calibration Module (temperature module)
PCO
Power Cord 115VAC (8 ft./2,44 meters with plug and strain relief) - NOT for 230VAC use
SMP50
Surface Mounting Plate
RA
Remote Alarm™ (Monitor/controllers only)
VR
Power Supply, 115 VAC to 24 VAC, 20VA. (indoor use only)
024-1
1in. NPT 24 VAC Solenoid Valve
CS-11
20 Megohms Resistivity Calibration Module (sensor substitute) NIST Traceable
CS-14
2 Megohms Resistivity Calibration Module (sensor substitute) NIST Traceable
CS-17
200 Kilohms Resistivity Calibration Module (sensor substitute) NIST Traceable
CC or RC
NIST Certificate without sensor (C = Cond or R = Res)
CCATF or RCATF NIST Certificate without sensor, ordered after instrument has shipped (C=Cond or R=Res)
CCS
NIST Certificate with sensor, using standard solution (Conductivity/TDS only)
* Does not fit into enclosure, must be mounted separately (Customer Installed).