This control effectively regulates heating mantles, tapes and cords .

Minitrol may also be used for small furnaces or ovens, hot plates, dies
or other applications requiring infinite control . The control should not be
exposed to ambient temperatures above 125°F (52°C) .

In addition to Minitrol, stock is maintained on variable transformers and
automated controls . Write to the address below for more information:

Glas-Col apparatus Company

711 Hulman Street
Terre Haute, Indiana 47802

812 – 235 – 6167

Section 16

Arctic Pak Hose Replacement Set

16 .1 General Information

In ambient temperatures below 65°F (18°C), use of arctic Pak heated
chemical hoses is often required for consistent, quality results . The

arctic Pak will keep the chemicals at an even, warm temperature to

allow uniform processing .

This product is primarily intended to keep already warmed materials at

temperature during transit to the dispensing InSTa-FlO™ Gun . Chemi-
cal tanks should be stored in a warm location until use, and may require
use of a tank heater band set (please see Section 15) .

The arctic Pak is used in place of unheated chemical transport lines

where described throughout this manual (Sections 3 .3 and elsewhere) .

dO nOT use standard 30 foot FROTH-PaK hoses in an arctic Pak
heated jacket .

dO nOT use arctic Pak hoses in place of nitrogen lines or for

conveying non-polyurethane chemicals of any type .

dO nOT use the arctic Pak with any flammable materials .

Standard unheated chemical lines are 30 feet in length, but are often
connected in series to produce longer lengths as job needs require .
locate unneeded hose (if any) out of the traffic path to prevent a trip

hazard . never attempt to cut the arctic Pak to a shorted length or to
splice in additional hose .

The arctic Pak is fully pressure checked and is flushed with

nitrogen at the factory prior to shipment . To keep the hoses from having
moisture or other undesirable materials introduced into them, please
keep the hose end plugs in place
until beginning installation .

16 .2 Preparing and Installing the Arctic Pak

1 . unpack and examine your arctic Pak for possible

shipping damage . Do not use if damage has occurred .

2 . as per Section 3 .3, connect your Gun/Hose assembly

to the in-line on-off valves .

3 . Remove plugs from the dispenser end of the hose .

The dispenser end is the end without the electrical

cord entering it . Connect the in-line on-off valves to

the dispenser end of the arctic Pak hoses and tighten

securely . Close the on-off valves if not already closed .

4 . The electrical cord servicing the heaters enters at the

tank end of the jacket . Remove plugs from the tank

end of the hose .

5 . Connect the tank end of each hose to the appropriate

chemical tank on-off valve . The hose with the red

colored sleeve and blue body should connect to the

isocyanate tank . The blue sleeved, black bodied hose

should connect to the polyol tank . Close the on-off

valves if not already closed .

6 . Follow the remaining operating manual instructions

for Chemical Hose Installation (Section 3 .3) . also

execute the instructions regarding System Pressuriza-

tion (Section 4 .1), and System Purging and Testing

(Section 4 .3) as they are the same for both heated and

24