Installation Procedures for THERMAX

Light Duty Insulation on Tilt-up Walls

®™Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow

*International Energy Conservation Code (IECC) at www.energycodes.gov and American Society of Heating, Refrigerating and Air-Conditioning Engineers at www.ashrae.org

THERMAX

Light Duty Insulation,

when installed on the interior of

tilt-up concrete walls, enhances the

building’s thermal performance and

moisture management and helps meet

continuous insulation requirements

mandated by energy efficiency codes

and standards, such as IECC and

ASHRAE 90.1.* The product can

be installed exposed to the interior

without a thermal barrier.

THERMAX

Light Duty Insulation

is lightweight and easy to install and

can be adhered directly to concrete

or masonry walls. It consists of a

glass-fiber-reinforced polyisocyanurate

foam core laminated with a 1.25

mil embossed white acrylic-coated

aluminum facer on one side and

1.25 mil embossed aluminum on

the other side. The facers make it a

durable choice for use in light-impact

areas. It can be pressure-washed up to

1,000 psi with a 15-degree or greater

spray tip (at minimum 3' distance).

MATERIALS CHECKLIST

• THERMAX

Light Duty Insulation

(code-approved thickness at

minimum)

• Utility knife or small handsaw

• Straight edge

• Measuring tape

• Pencil

• Pneumatic nailer (or equivalent)

• PVC (polyvinyl chloride) interlocking

system (Figure 1)

• Self-impaling nails/fasteners and

1.25" diameter (min.) plastic washers

• Construction-grade adhesive

• Silicone, polyurethane or butyl

sealant (Table 1)

• Safety glasses

INSTALLING THERMAX

LIGHT DUTY INSULATION

1. Install THERMAX

Light Duty

Insulation boards along the bottom

perimeter of the interior walls by

applying a 3/8" bead on the back

side of boards at 5' horizontally.

2. Apply a 3/8" bead of polyurethane

or butyl caulk to the top of each

board and around each cut pen-

etration (joist pockets, conduits,

cutouts, etc.).

3. Install PVC interlocking system

vertically with self-impaling nails/

fasteners and washers (Figure 1).

4. Fasten nails/fasteners and wash-

ers through front face of insulation

board at 5' o.c. vertically.

5. Apply a 3/8" bead of sealant to

the bottom flange of all J-Channel

molding (Figure 2).

Tilt-up Wall with THERMAX™ Light Duty Insulation

TABLE 1: RECOMMENDED SEALANTS FOR USE WITH

THERMAX™ LIGHT DUTY INSULATION

MATERIAL

RECOMMENDED SEALANT

Silicone

Dow Corning 790 Silicone Building Sealant

Polyurethane

Sika Sikaflex-201 US Polyurethane Sealant

Polyurethane

Schnee-Morehead Permathane SM7108 Polyurethane Sealant

Butyl

Tremco Vulkem 116 Sealant

PVC Strips