Shut-down Procedure

1 . Remove the used nozzle by pushing down on the

nozzle ejector .

2 . apply petroleum jelly to the face of the InSTa-FlO™ Gun .

3 . Reinsert the used nozzle . This provides an airtight

seal during storage .

4 . Turn off the in-line on-off valves . The valve handles

should be perpendicular to the chemical lines .

5 . Turn off the on-off valves located near the chemical filters .

The valve handles should be perpendicular to the

chemical lines .

6 . Turn off the chemical tank valves of the “a” and “B” tanks . The

handles should be perpendicular to the valves .

7 . Turn off the yellow-coded nitrogen intake valves of the “a” and

“B” tanks . The handles should be perpendicular to the valves .

8 . Turn off the nitrogen cylinder by turning the valve on the top

of the nitrogen cylinder in a clockwise direction .

9 . Back out both nitrogen regulator valve stems until they are

freewheeling .

10 . Coil the chemical lines to prevent possible tripping

and damage .

Section 7

Storage

1 . Store in a dry area .

2 . Store between 60°–80°F (16°–27°C) .

3 . Short term storage between 45°–60°F (7°–16°C) is permitted .

4 .

dO nOT store at temperatures above 120°F (49°C) .

5 .

dO nOT not store near steam or hot water pipes .

6 .

dO nOT store near chimneys or heat vents .

7 . If a partially used system remains inactive for a period of time,
the system should be pressurized and purged every two weeks .
This will prevent crystallization of the chemical in the hoses .

8 . unopened chemical tanks have a shelf life of approximately

one year .

Section 8

dO nOT breathe vapor or spray . Proper Personal Protective Equipment
and ventilation are required . See product SDS and Section 2 of this
manual for further information . Follow all precautions for product .

Re-Start-Up

1 . Open the nitrogen valve fully to pressurize the system .

2 . Open the two sets of valves on the chemical tanks for the a and
B sides and then the valves on the gun .

3 . Remove the cured nozzle that you left attached to the gun .

4 . Spray into a waste container . Ensure that you have good flow

from both the a and B side hoses .

5 . Clean the face of the gun . attach a new nozzle .

6 . Spray a test sample to ensure good quality foam .

7 . Resume spraying .

Re-start Procedure

8 .1 System Pressurization

1 . Verify that the valve stems on the regulator are backed

out and are freewheeling .

2 . Open the nitrogen bottle valve by turning the knob on top of
the cylinder counter-clockwise . If a hissing sound occurs,
further tighten the nitrogen regulator valve stem with an
adjustable wrench . use only in well ventilated areas . Wear
suitable respiratory protection .

15