Dow FROTH-PAK Refill Systems User Manual
Page 31
dow Building Solutions
Section 15
Tank Heating
15 .1 Usage
In places where the FROTH-PaK™ Refill System is used where the
ambient temperature is below 65°F (18°C), an external source to heat
the chemical in the tanks may be required .
Heating bands are available for both the 17 gallon and the 60 gallon
tanks, through:
McMaster-Carr
www .mcmaster .com
630-600-3600
The heater band McMaster model numbers are as follows:
17 gallon: 3545K42
60 gallon: 3545K44
Control boxes are available through:
Glas-Col apparatus Company
711 Hulman Street, P .O . Box 2128
Terre Haute, In 47802
812 - 235 - 6167
The model number for the control box is Pl-312 .
During the initial start-up, the controls for the heater bands can be set at
3 or 4 for two hours . However, for continuous operation, “lO” would be
the desired setting, unless extremely low temperatures are experienced .
15 .2 Installation Procedure - Tank Heater Band
1 . Wrap and clamp heater band around tank prior to switching on .
2 . Pull on spring, at the same time hold end of heater
against the tank .
3 . Place a loop of the spring over the hook .
4 . The heater should not be clamped in dented areas of the tank .
5 . The heater must be in full contact with the tank and
below the level of the liquid while in operation .
6 . DO nOT bend the heater sharply as this may cause
internal damage to the heating element .
7 . DO nOT use outside insulation .
NOTE: Heaters are available for other tank heating operations, refer to
Electro-Flex Heat, Inc.
15 .3 POWERBLANKET
®
warming equipment
POWERBlanKET warming equipment also keeps your jobs on
schedule during the colder months . Delivering a barrier of insulated
heat to the spray foam . Powerblanket creates an optimal application
environment . For more information, call Customer Service at
877-398-7407 . To order, call 801-456-8013 and refer to the item
numbers below:
• DOW-17 (17-gallon tank heater)
• DOW-27 (27-gallon tank heater)
• DOW-60 (60-gallon tank heater)
• DOW-620 (620& 650 -bf single-component cylinder heater)
• DOW-200 (200 & 210 -bf a & B disposable box heater)
• DOW-55RR (Rapid Ramp 55-gallon drum heater)
• DOW-55PRO (Pro series 55-gallon drum heater
and thermostatic controller)
• DOW-GHT (Digital thermostatic controller)
15 .4
Glas-Col Power Control Description and Operation
The Glas-Col Minitrol is a manually adjusted power control of
percentage timer design . Minitrol is designed to proportion full output
power 5 .5% to 100% of time depending on the dial setting . The “Off ”
position positively breaks both sides of the line .
The control can be used on any non-inductive fused resistance load up
to 15 amps and 120 volts . Smaller fuses may be used for protection of
very small loads . Simply plug device into a 3-wire outlet of the control
and insert plug of Minitrol cord into a wall receptacle . The pilot light is
connected across the output side of the control and indicates power to
the load .
Minitrol’s operation and control is adjusted by the operator and does
not utilize a sensing element . after a desired temperature has been
determined on the initial run, a simple resetting of the dial offers
control for repeat operations .
23
dial Setting
Percent of time on
Off
0
Lo
5.5 (approx.)
4
35 (approx.)
6
52 (approx.)
Hi
100