beautypg.com

Vaddio WallVIEW CCU Kit for AW HE-120 User Manual

Page 8

background image

Quick Connect CCU Kit and WallVIEW Kit for the AW-HE120

© 2012 Vaddio - All Rights Reserved. Document Number 342-0498 Rev A Page 8 of 16

Please do not use “pass-thru” type RJ-45 connectors. The Vaddio Cat-5 wiring standard uses
pins 7 and 8 on both the video and the control Cat-5e cables. The pass-through connectors have
proven to provide insufficient connectivity for these important signals. They are “ok” for voice and
data, but not for video and control.

Step By Step Mounting Instructions:

Step 1:
After determining the optimum location of the camera system, mark locations for the four screw holes and cable
pass-thru (vertical oval). Install the drywall mounts and cut the hole for the cable pass-thru. At this point, do not
install the Wall Mount.

Image: Heavy duty wall mount

The wall mount may be mounted directly to a 3-gang wall box or to drywall
with the appropriate wall anchors.



Step 2:
Connect the break out cable to the EZIM CCU. Mount the EZIM CCU and break out cable in the back of the wall
mount, using the supplied screws and two tapped screw holes.

Image: Heavy Duty Wall Mount

Wall mount shown with EZIM CCU and HD break out cable attached to
the back of the mount.












Drawing: High Definition Break Out Cable
















DB-25-M
plugs into
EZIM CCU

12 VDC Power on
3mm ID Connector

RS-232 to RS-
422 converter
and adapter

CVBS on
BNC-M

G/L on
BNC-M

YPbPr on
DE-15-M

Exact Cable
Not Shown

This manual is related to the following products: