8

How to install and connect the unit

Be absolutely sure to read through the “Read this first!” (page 5) and “Installation precautions” (pages 6 to 7).

The procedure given here is for the kind of installation where the unit is suspended from an overhead surface, but the same
steps are followed for a stand-alone installation.

If the ceiling panel is not strong enough to bear the unit’s weight, use the kind of mount bracket that is supported
by anchor bolts between the concrete ceiling and ceiling panel. The unit supports the WV-Q105 direct ceiling mount
bracket which is used solely for combination cameras. Use this bracket to install the unit. (See page 12)
In a case like this, the holes (ø 60 mm [ø 2-3/8 inches]) for installing the direct ceiling mount bracket on the ceiling
must be drilled in the ceiling panel.
It is also recommended that you provide an inspection space or opening for access purposes in the area near where
the equipment is installed in order to facilitate installation and the wiring connections work.
See page 31 for details of the accessories.

1

Check the mounting space.

Refer to the illustration, and determine where the unit is to be installed and in which direction it should be mounted.
Factor in the unit mounting area and include space for the wires extending from its rear panel.

The asterisk (

) in the illustration marks the position and dimensions of the hole for mounting the mount bracket.

160 (6-5/16)

(Space for the wires from the

rear panel)

320 (12-19/32) or more

(Space f

or the wires)

90 (3-17/32)

88 (3-15/32)

136 (5-11/32)

108 (4-1/4)

(

)83.5

(3-9/32)

176 (6-15/16)

180 (7-3/32)

Hole for checking the positioning

The front panel of the unit on this side.

Unit: mm (inch)

Mount bracket

Hook for mounting the
drop-prevention wire

Unit mounting area

Through-hole for cable
ø 40 mm (ø 1-9/16 inches)
(reference)

(

) Holes for mounting the

mount bracket: ø 4.5 mm

4

Hole for mounting the
main unit mounting screw

Hole for installing the WV-Q105
direct ceiling mount bracket
[ø 60 mm (ø 2-3/8 inches)]

(

)46 (1-13/16)

Before proceeding to install and connect the main unit, connect the LAN cable, HDMI cable, VGA cable, AC adaptor
cable and coaxial cables in the space above the ceiling panel, and then pass the cables through the cable holes.

For a power outlet which is used on the ceiling, be absolutely sure to take measures to deal with the tracking that may
be caused by the accumulation of dust and other foreign matter.

Notes