Alarm history at the hdsl2 interface, H2tu-c hdsl2 alarm history screen, Hdsl2 alarm descriptions – ADC H2TU-C-388 User Manual
Page 41
152-388-100-02, Issue 2
Monitoring System Activity and Performance
H2TU-C-388 List 1
June 6, 2000
33
Alarm History at the HDSL2 Interface
shows the H2TU-C HDSL2 alarm history, and
describes the alarms.
Figure 23.
H2TU-C HDSL2 Alarm History Screen
Table 12.
HDSL2 Alarm Descriptions
Screen Alarm
Front-Panel Alarm Description
HDSL2 ALARMS at the H2TU-C and H2TU-R
LOSW
LOSW
Loss of Sync Word—The HDSL2 loop has lost synchronization.
MAL
MAL
Margin—The margin on the HDSL2 loop has dropped below the minimum threshold value
set for the system.
LA
LA
Loop Attenuation—The attenuation on the HDSL2 loop has exceeded the maximum value
set for the HDSL2 loop attenuation threshold.
HBER
HBER
Block Error Rate—The HDSL2 BER has exceeded the set threshold limits of
10
-6
or 10
- 7
.
HDSL2 ALARMS at the H2TU-C only
SHORT
PWR FEED SHRT
Indicates a short between the Tip and Ring of the HDSL2 pair.
GND
PWR FEED GND
The HDSL2 loop is grounded.
OPEN
PWR FEED OPEN
Indicates a line power open condition.
Monitor
Performance
Event Log
Config
Inventory
Rlogon
Help
H2TU-C HDSL2 Alarm History
------------------------------------------------------------------------------
Alarm
First
Last
Status
Count
LOSW
04/03/00 00:00
04/03/00 00:45
ALARM
12
MAL
OK
0
LA
OK
0
HBER
04/03/00 00:37
04/03/00 00:45
OK
7
SHORT
OK
0
GND
OK
0
OPEN
OK
0
Press: C(l)ear Alarm History
------------------------------------------------------------------------------
Press
Interface
: H2TU-C HDSL2
choices and
Statistics :
Alarm History
ID: xxxx--xxxx--xxxx--xxxx
04/15/00 12:30:01
H2TU-C
System: Alarm