Front-panel display messages – ADC H2TU-C-388 User Manual
Page 13
152-388-100-02, Issue 2
Front Panel
H2TU-C-388 List 1
June 6, 2000
5
lists the front-panel display messages. The four-character display reports the code of an alarm, loopback,
or diagnostic message and, in some cases, is followed by a second four-character message that modifies the first
message with a value or current configuration setting.
Table 2.
Front-Panel Display Messages
Message
Full Name
Description
SYSTEM ALARM MESSAGES
ACO
Alarm Cutoff
A system alarm has occurred and has been retired to an ACO condition
by pressing the SEL button on the H2TU-C front panel.
ALRM
Alarm Condition Exists
A system alarm condition is in effect.
DBER
DS1 Bit Error Rate
A system DS1 BER alarm is in effect and remains in effect until cleared.
HBER
HDSL2 Block Error Rate
A system HDSL2 Block Error Rate alarm is in effect.
LA
Loop Attenuation
Indicates that the attenuation on the HDSL2 loop has exceeded the
maximum threshold value.
LAIS
Local Alarm Indication Signal
Indicates an AIS (all ones) pattern is being transmitted from the local
DS1 output port.
LLOS
Local Loss of Signal
Indicates that no signal is detected at the DSX-1 input to the H2TU-C.
Causes a system alarm.
LOSW
Loss of Sync Word
Indicates that the HDSL2 loop has lost synchronization.
LRAI
Line RAI
Indicates an RAI alarm (yellow) from the CPE with an error-free signal
from the line unit or network.
MAL
Margin Alarm
The margin on HDSL2 loop has dropped below the threshold (0 to 15
dB) as set by the operator.
PWR FEED GND
Ground
The HDSL2 loop is grounded.
PWR FEED OPEN
Open
Indicates a line power open condition.
PWR FEED SHRT
Short
Indicates a short between the Tip and Ring of the HDSL2 pair.
PRMF
Performance Report Messaging -
Far End
H2TU-R PRM-FE BER threshold has been exceeded.
PRMN
Performance Report Messaging -
Near End
H2TU-R PRM-NE BER threshold has been exceeded.
RAIS
Remote Alarm Indication Signal
Indicates an AIS (all ones) pattern is being transmitted from the remote
DS1 output port.
RLOS
Remote Loss of Signal
Indicates that no signal is detected at the DS1 input to the H2TU-R.
Causes a system alarm.
RRAI
Remote RAI
Indicates an RAI alarm (yellow) from the CPE with errors from the line
unit or network.
TUC
Transmission Unit Central Office
Accompanies the HBER, MAL, and LA alarm and indicates that the alarm
has occurred at the H2TU-C central office unit.
TUR
Transmission Unit Remote End
Accompanies the HBER, MAL, and LA alarm and indicates that the alarm
has occurred at the H2TU-R remote unit.
LOOPBACK MESSAGES
CLOC
Customer Local Loopback
Signal from customer is looped back to the customer at the H2TU-R.
COLB
Central Office Loopback
Dual loopback at the H2TU-C.
CREM
Customer Remote Loopback
Signal from customer is looped back to the customer at the H2TU-C.
NLOC
Network Local Loopback
DSX-1 signal is looped back to the network at the H2TU-C.
NREM
Network Remote Loopback
DSX-1 signal is looped back to the network at the H2TU-R.
RULB
Remote Unit Loopback
Dual loopback at the H2TU-R.
Continued