Agilent Technologies HSSI WanProbe J3916A User Manual
Page 58

Local Terminal Configuration
Using the Main Menu
38
4. Press a number to select a field and then type the corresponding values
necessary to configure the probe to operate on your network.
Serial port IP address
Press
3
and then type the serial port IP address for the
probe. The default Serial Port IP Address is
0.0.0.0
.
Serial port
Press
4
and then type the serial port subnet mask for
subnet mask
the probe (optional). It is recommended that you do not
change the serial port subnet mask unless there is a
conflict. The default Serial Port Subnet Mask is
255.255.255.192.
Serial port speed
Press
5
and then type a serial port speed (300 to 38,400
baud) for the probe’s SNMP connection. The default is
9600 baud. This speed is used only for Out-of-Band
access to the probe using SNMP. It does not affect the
serial connection for the local terminal, which is fixed at
9600 baud.
Make sure that the serial port speed is set to less than or
equal to the maximum speed of the modem to be used.
Serial port mode
Press
6
and then select the serial port mode by pressing
1
for direct connection (the default) or
2
for modem
connection.
Serial port hardware
Press
7
and then select hardware flow control Off by
flow control
pressing
1
or hardware flow control On (the default) by
pressing
2
.
Modem Init String
Press
8
and then type the modem initialization string.
Only the first 20 characters of the 256 character
maximum will be displayed in the Modify/View Serial
Port Settings menu. The default is
^s^M^d1^sATEOQOV1X4 S0=1 S2=43^M
.