beautypg.com

Bluetooth tests, Ethernet controller tests – Apple MAC PRO for 3X108 User Manual

Page 45

background image

Appendix

Server Diagnostics Test Reference

45

Bluetooth Tests

Test

Estimated completion time

Description

Bluetooth USB Interface

1 second

Verifies USB interface between
host and Bluetooth.

MAC Address Verification

1 second

Verifies MAC address isn’t all FFs
or 00s.

Bluetooth Power Cycle

10 seconds

Verifies USB interface between
host and Bluetooth after turning
Bluetooth power off and then
turning Bluetooth power on.

Ethernet Controller Tests

Data loop tests can add to network traffic. Consider disconnecting from the network
before running data loop tests.

Test

Estimated completion time

Description

MAC Address Verification

1 second

Verifies MAC address isn’t all FFs
or 00s.

MAC Loopback

25 seconds

Verifies that there’s no data
mismatch between sent and
received data while looping
within the MAC (a sublayer of
the datalink layer in the ISO
network reference model).

PHY 1000 Loopback

25 seconds per port

Verifies that there’s no data
mismatch between sent and
received data while looping
within the physical transport
medium (PHY) at 1000 Mbps.

PHY Jumbo Packet Loopback

25 seconds per port

Verifies that there’s no data
mismatch between sent and
received jumbo packet data
while looping within the
physical transport medium
(PHY) at the the highest
supported speed.