Setting alarm activation level, Installing the translation file – Avaya S8710 User Manual
Page 48

3 Translating the IPSIs
Administering the IPSIs
48
Installing and Configuring the Avaya S8700 or S8710 Media Server
June 2004
Setting alarm activation level
1
Type
change system-parameters maintenance
and press Enter.
2
In the
CPE Alarm Activation Level
field, select
none
(default),
warning
,
minor
, or
major
,
depending on the level the customer wants and press
Enter
to effect the changes.
3
Repeat for each IPSI.
Installing the translation file
1
Type
save translations
and press Enter to save the translations to the hard drive.
change system-parameters maintenance
Page 1 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
CPE Alarm Activation Level: none
SCHEDULED MAINTENANCE
Start Time: 22 : 00
Stop Time: 06 : 00
Save Translation: daily
Update LSPs When Saving Translations: y
Command Time-out (hours): 2
Control Channel Interchange: no
System Clocks/IPSI Interchange: no