beautypg.com

H. system installation, For authorized specialists only – Karcher HDR 777-VA User Manual

Page 35

background image

HDR 777

English

5.959-106 A2006570 09/03

FOR AUTHORIZED SPECIALISTS ONLY

FOR AUTHORIZED SPECIALISTS ONLY

H. System installation

H2

8. Connections

A Drain tap

B Overflow (size DN 50), reaction tank

C Feedthrough for connecting cable from

waste-water pump

D Fresh-water supply (size DN 19)

*) on rear of system

E Recycling water discharge (DN 25)

F Emergency overflow, filter unit

(size DN 29)

G Waste-water inlet (size DN 25)

H Discharge to the sewerage system or

external consumers

6. Settings and adjustments

Dosage of chemical agents

The splitting agent and degerminating agent
dosages have been set up in the factory to
an average value.

i

Important!

The dosages must be matched on site to the
degree of contamination in the waste water
by a Customer Service engineer.

Operating mode

The operating mode (water either recycled
or discharged into sewers) must be set up
by Customer Service.

7. Filling up with chemicals

This task can be carried out by the operator.

(See Section B.3: Prior to start-up)

H F

E B*

C*

D* A

G

This manual is related to the following products: