F3

Problem

Possible cause

Remedy

By whom

Size of floc is inadequate

Metered quantity of cleavage
powder or liquid cleavage

agent too low

Settling period after agitation
is too short

Agitation is not carried out
entirely correctly

Bypass pump (18)
underneath reaction tank is
not working

Increase metered quantities

Extend rest period

Determine cause and rectify accordingly

Check supply voltage and replace pump,
if necessary

Customer
Service

Customer
Service

Customer
Service

Customer
Service

Filter is full after only a few

splitting processes

Hose connecting reaction

tank to cascade filter is not

inserted into hole provided
in filter

Floc is too small and is

clogging up filter fleece

Rectify as necessary

Optimize flocculation process (splitting agent
metering and settling period)

Operator

Customer
Service

No pressure at high-
pressure cleaner

Water deficiency, air is taken

in or high-pressure

appliance is connected
wrongly

Determine cause and rectify accordingly

Customer
Service

Water escapes from one
of the overflows (B, F, H)

(see Chapter H.4)

Overflow hoses are not
connected

Connect overflows

Customer
Service

Stirrer motor and drainage
pumps (16, 17) don’t
switch off after draining the
reaction tank

Stirrer shaft soiled or contact
problem

Clean or replace

Operator/
Customer
Service