Show server security command, Show server snmp command – Avocent CCM User Manual
Page 96
82 CCM Installer/User Guide
Access right: SMON
Access level: ADMIN or APPLIANCEADMIN
Syntax
SHOW SERVER RADIUS
Show Server Security command
The Show Server Security command displays the current authentication, connection and lock-out
settings that were configured with the Server Security and Server SSH commands.
Access right: SMON
Access level: ADMIN or APPLIANCEADMIN
Syntax
SHOW SERVER SECURITY
Show Server SNMP command
The Show Server SNMP command displays SNMP configuration information.
Access right: SMON
Access level: ADMIN or APPLIANCEADMIN
Syntax
SHOW SERVER SNMP
Table 5.34: Show Server Security Command Display Fields
Field
Contents
Authentication
Configured authentication method(s). This includes the SSH authentication method
configured with the Server SSH command (or the default value), regardless of
whether SSH is enabled.
Encryption
Configured connection methods.
Lockout
Configured security lock-out state (Enabled or Disabled). If Enabled, the number of
hours in the lock-out period is included.
Fingerprint (Hex)
SSH key MD5 hash.
Fingerprint (BB)
SSH key bubble babble.
Table 5.35: Show Server SNMP Command Display Fields
Field
Contents
Server SNMP
ENABLE if SNMP processing is enabled, DISABLE if SNMP processing is disabled
(from Server SNMP command).
Read Community
Read community name (from Server SNMP Community command).