beautypg.com

Show server security command, Show server snmp command – Avocent CCM User Manual

Page 96

background image

82 CCM Installer/User Guide

Access right: SMON
Access level: ADMIN or APPLIANCEADMIN

Syntax

SHOW SERVER RADIUS

Show Server Security command

The Show Server Security command displays the current authentication, connection and lock-out
settings that were configured with the Server Security and Server SSH commands.
Access right: SMON
Access level: ADMIN or APPLIANCEADMIN

Syntax

SHOW SERVER SECURITY

Show Server SNMP command

The Show Server SNMP command displays SNMP configuration information.
Access right: SMON
Access level: ADMIN or APPLIANCEADMIN

Syntax

SHOW SERVER SNMP

Table 5.34: Show Server Security Command Display Fields

Field

Contents

Authentication

Configured authentication method(s). This includes the SSH authentication method
configured with the Server SSH command (or the default value), regardless of
whether SSH is enabled.

Encryption

Configured connection methods.

Lockout

Configured security lock-out state (Enabled or Disabled). If Enabled, the number of
hours in the lock-out period is included.

Fingerprint (Hex)

SSH key MD5 hash.

Fingerprint (BB)

SSH key bubble babble.

Table 5.35: Show Server SNMP Command Display Fields

Field

Contents

Server SNMP

ENABLE if SNMP processing is enabled, DISABLE if SNMP processing is disabled
(from Server SNMP command).

Read Community

Read community name (from Server SNMP Community command).