beautypg.com

Connection examples, Nconnection of relay 1 only – Aiphone JK-DVF-AC User Manual

Page 7

background image

6

English

Français

Nederlands

n

Connection of Relay 1 only

Electric door strike

AC transformer

Power supply

2 NP

2 NP

2 NP

2 NP

2 NP

2

NP

2

NP

Automatic gate

Power supply

Request to exit/entry button
(push button, etc.)

Electromagnetic

door lock

V

V

PB1 PB2

C

T

NO1 C1

NC1 NO2

C2 NC2

NO1 C1

NC1 N

NO1 C1

PS

NC1 NO2 C

A1

A2

JK-1MD

JK-1MED

JK-1MED/1MD

A1 A2

L

L

JK-DVF-AC

n

Relay 1: Automatic gate (N/O contact), Relay 2: Electric door strike (N/O contact)

Power supply
Rating
Between 12 and 24V AC
Between 12 and 24V DC

Automatic gate

Timer

For relay 2
Request to
exit/entry button

For relay 1
Request to
exit/entry button

To set the

"auto-relock" / "External output by forced entry" function,

a sensor (locally available) is required.

The request to exit/entry button for relay 2 cannot be used when the

"auto-relock" / "External output by forced entry" functions are set.

Electric door strike

AC transformer

Auto-relock/External output by forced entry
(sensor connection is required)

2

NP

2

NP

A1

A2

JK-1MD

JK-1MED

A1 A2

L

L

V

V

PB1 PB2

C

T

NO1 C1

NC1 NO2

C2 NC2

Alarm, Security

Only connecting to the terminal
of relay 2 is possible.

External output

NO2 C2

2 NP

2

NP

2

NP

2

NP

2 NP

2 NP

PB2

N.C

C

JK-DVF-AC

JK-1MED/1MD

or

or

or

or

Example of electric door

strike connection (N/O)

Example of automatic

gate connection (N/O)

Example of electromagnetic

door lock connection (N/C)

Connection examples

JK-DVF-AC_ENG.indd 6

2009/10/05 21:18:39