VERTICAL CONTACT TOASTER
P/N 1010719 Rev. E 02/13
TROUBLESHOOTING
WARNING
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-
ment should be performed by qualified service personnel. The unit should be unplugged when servicing,
except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will
be exposed.
No heat and conveyor belts
do not move.
No heat and conveyor belts
move.
Toaster is installed incorrectly.
No voltage, defective power cord,
defective rocker switch.
Hi-limit switch tripped open.
Wiring problem.
Wiring problem.
Inoperative temperature display
control or platen.
Perform installation and operating proce-
dures (pages 6-11).
Check receptacle for correct voltage. See
Specifications (page 4).
With unit plugged in and rocker switch on,
check for correct voltage into rocker switch.
If low or zero voltage, replace power cord.
If voltage is correct, check for correct volt-
age out of rocker switch. If low or no volt-
age, replace rocker switch.
Reset hi-limit switch (Fig. 5, page 8).
Check all electrical connections for burns,
discoloration or arcing. Replace all connec-
tions or components with damaged termi-
nals. Replace all damaged wiring with the
same (or higher) rated wire.
Check all electrical connections for burns,
discoloration or arcing. Replace all connec-
tions or components with damaged termi-
nals. Replace all damaged wiring with the
same (or higher) rated wire.
To check temperature display control, allow
unit to warm up for 30 minutes, then:
1. Check platen temperature at the center
of platen (with conveyor belt wrap, con-
veyor belt, tensioners and release sheet
removed). Use a pyrometer to confirm
temperature readings.
2. After platen temperature reaches a maxi-
mum of
559°- 561°F (292°- 293°C) and
auxiliary heaters reach a maximum of
339°- 341°F (170°- 172°C), and the tem-
perature begins to drop, the heat indica-
tor light on the temperature control board
should turn on. If test readings do not
agree with these figures, replace temper-
ature display control.
Problem
Possible Cause
Corrective Action