beautypg.com

ROTHENBERGER ROWELD P250-630 B Plus Premium CNC User Manual

Page 52

background image

ENGLISH

50

P003

Heating plate temperature offset 5

°C

-25

25

Welder

P004

Pmax for cutting

20

bar

10

50

Welder

P005

Target pressure

1/10 bar

Welder

P006

Target temperature

210

°C

P103 P104

Welder

P007

Timer T1 target value

45

sec

1

1500 Welder

P008

Timer T4 target value

6

min

1

99

Welder

P009

Pstart for cutting

10

bar

0

P004

Welder

P101

Deviation for repumping

5

%

1

50

Master

P102

Lifting time after cutting

10

1/10 sec 0

100

Master

P103

Set temperature (min)

160

°C

0

300

Master

P104

Set temperature (max)

270

°C

0

300

Master

P105

Button lock (yes/no)

5

sed

0

50

Master

P106

Lifting pressure

135

bar

10

160

Master

P107

Full runtime until buzzer goes on 50

1/10 sec 0

200

Master

P100

Change code

8001

Master

* P002 - Power saving function:

0 - none,
1 - when the miller is running the heating element will be switched off,
2 - when the hydraulic motor is running the heating element will be switched off,
3 - when t4 is running the heating element will be switched off.

3.6 Set date and time

Close the program by clicking briefly in the upper left corner.

Press Start, Setting and then Control Panel.

The taskbar is hidden and can be called back up by pressing on the lower left corner.

This manual is related to the following products: