ENGLISH
50
P003
Heating plate temperature offset 5
°C
-25
25
Welder
P004
Pmax for cutting
20
bar
10
50
Welder
P005
Target pressure
1/10 bar
Welder
P006
Target temperature
210
°C
P103 P104
Welder
P007
Timer T1 target value
45
sec
1
1500 Welder
P008
Timer T4 target value
6
min
1
99
Welder
P009
Pstart for cutting
10
bar
0
P004
Welder
P101
Deviation for repumping
5
%
1
50
Master
P102
Lifting time after cutting
10
1/10 sec 0
100
Master
P103
Set temperature (min)
160
°C
0
300
Master
P104
Set temperature (max)
270
°C
0
300
Master
P105
Button lock (yes/no)
5
sed
0
50
Master
P106
Lifting pressure
135
bar
10
160
Master
P107
Full runtime until buzzer goes on 50
1/10 sec 0
200
Master
P100
Change code
8001
Master
* P002 - Power saving function:
0 - none,
1 - when the miller is running the heating element will be switched off,
2 - when the hydraulic motor is running the heating element will be switched off,
3 - when t4 is running the heating element will be switched off.
3.6 Set date and time
Close the program by clicking briefly in the upper left corner.
Press Start, Setting and then Control Panel.
The taskbar is hidden and can be called back up by pressing on the lower left corner.