ENGLISH

40

The form shows the temperature of the heating plate.

The display bar shows up in blue if the temperature is too low, and in red when it is too high.
When it is in the target range, it displays as green.
The machine can only be run in the green target range.

Heating plate SA: Insert the heating element between the two work pieces in the basic
machine, and make sure that the heating plate supports are seated in the notches of the
removal device.

Heating plate VA: Place the heating element on both acceptance points in the basic
machine and swivel the hot plates between the pipes.

Move the machine together by pressing the text field. The adjusting pressure is automatically
adjusted and maintained.

Now all welding parameters have been stored, and the log activated.
If the welding process is interrupted using EXIT the message “Termination by the operator“
appears, the pressure is dissipated and the welding parameters are stored. Confirm the
message with OK, then the programme jumps to the main menu.

The upper progress bar shows whether the pressure lies within the correct range (green) or
within a permissible (yellow) tolerance range or whether it lies outside (red) the tolerance
range. The actual pressure is shown on the display (2).

As soon as the necessary bulge height has been uniformly reached on the entire
circumference of both tubes, the pressure is automatically released and the warm-up process
begins.