beautypg.com

Service connections – Blodgett CB-G SERIES User Manual

Page 4

background image

4

SERVICE CONNECTIONS

S

B

A

M

C

D

6

[1

52

]

28

[7

11

]

55

[1

39

7]

L

K

J

E

G

H

33

[8

38

]

24 [610]

36 [914]

CB24-140G AND CB24-200G

F

S

CB36-140G, CB36-200G,CB36-250 AND CB36-300G

DIMENSIONS ARE IN INCHES [MM]

S

WATER QUALITY STATEMENT

5.75

DIMENSIONS

MODEL

5.75

222

A

8.75

146

B

13.5

C

343

D

610

24

121

4.75

127

E

146

F

89

3.5

279

11

G

5

H

L

64

2.5

J

K

CB24-140G
CB24-200G

3

76

M

318

12.5

CB36-140G

CB36-200G

CB36-250G

CB36-300G

203

8

6

152

6.75

171

UNITS

inches

mm

140,000

BTU/HR

200,000
200,000
250,000
300,000

152

6

Unless otherwise specified, Field Wire Electrical Connection to be 120 Volts, 60 Hertz single phase with grounding wire.

DRAIN: 2"IPS piped to open floor drain. No Solid Connection.

COLD WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)

GAS CONNECTION: 3/4"IPS supply line required. Natural Gas : min.7" (178mm) Water Column. Propane : min.11" (279mm) Water Column.

STEAM TAKE-OFF: 3/4"IPS.

Less than 60 PPM
Less than 20 PPM
Less than 13 PPM
Less than 1.5 PPM

Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a
local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:

Water which fails to meet these standards should be treated by installation of a water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.

Total alkalinity

pH Factor

Total dissolved solids

Silica
Chlorine

7.0-8.5